prompt screens to be continued
........ Inspect Brake Air .... .
1/3
1. Increase brake
pressure slowly and
evenly.
2. At 10 bar the brake
pedal counterforce
is reduced but
........ Inspect Brake Air .... .
2/3
needs to be applied
further!
3. Brake pressure must
not rise beyond the
specified range!
4. Actual value should
........ Inspect Brake Air .... .
3/3
be within the black
range and be held
for 5s.
5. [Y] =Con. [N] =Return
22) Press Y button and following screen shows:
........ Inspect Brake Air .... .
11.8 bar
0 25
Hold pressure within
black range for 5s.
23) Actuate the pedal gently to raise the pressure to 20-24 bar and
keep it for 5s.
24) Follow onscreen instructions to complete operation of current
phase:
- The fill level of wheel brake circuit HZ2 (secondary brake
circuit) is in order.