Prompt screen to be continued…
........ Inspect Brake Air .... .
1/2
1. Increase brake
pressure slowly and
evenly.
2. Actual value should
be within the black
range and be held
........ Inspect Brake Air .... .
2/2
for 5s.
3. [Y] =Con. [N] =Return
17) Press Y button and following screen shows:
........ Inspect Brake Air .... .
7.8 bar
0 25
Hold pressure within
black range for 5s.
18) Actuate the pedal gently to raise the pressure to 10-20 bar and
keep it for 5s.
19) Follow onscreen instructions to complete operation of current
phase:
- The fill level of the pedal travel simulator is in order.
- Release brake pedal.
- Check fill status of wheel brake circuit HZ2 (secondary brake
circuit).
20) Press Y button or gently operate the pedal to continue, and the
device starts to communicate with the vehicle.
21) Use UP/DOWN button to view onscreen prompts
VS8622_1.03_12/03/09