4. APPLICATIONS
Original Language Version
VS8624Issue:1-16/07/10
3.5. Cable Unjam
3.5.1. Press Mode button to select correct type (EPB).
3.5.2. Press the Function button to select the appropriate EPB
operation.
3.5.3. Start the engine and run at idle.
3.5.4. Press the ‘OK’ button to activate the cable unjam
function.WhentheFunctionLEDashes,turnthe
ignition off.
3.5.5. If the function is unsuccessful, Mode LED Selection will
ash.
Note: As part of this process, the Clear codes routine is
automatically run to clear any codes within the EPB
system.
Note: For safety reasons we recommend removing the EPB
30Afusefromthebatteryjunctionbox.
3.6. Clear Codes
3.6.1. Press Mode button to select correct type (EPB).
3.6.2. Press the Function button to select the appropriate EPB
operation.
3.6.3. Press the ‘OK’ button to clear any stored codes within
theEPBmodule.TheFunctionLEDwillashtoindicate
clear codes was performed successfully.
3.6.4. If the function is unsuccessful, Mode LED Selection will
ash.
Note: Any codes that are not able to be cleared will remain on
the Module. Use the Sealey VST Electronic Auto Service
and Diagnostic Tool to determine what these codes are
and what steps need to be taken to resolve the problem.
LandRover-EPB/SERVICERESET
Model: Fuel Type: Year of Manufacture:
DISCOVERYIII (IfFitted) Petrol/Diesel 2005-2009
RANGEROVERSPORT (IfFitted) Petrol/Diesel 2005-2009
Cable Unjam