1. SAFETY INSTRUCTIONS
INSTRUCTIONS FOR:
POWER SCAN AUTOMOTIVE
PROBE/SCOPE 0-30V
MODEL No: PP100
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO
MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
2. INTRODUCTION AND DESCRIPTION
2.2 Description (fig.1)
2.2.1 Probe Tip – Contacts the circuit or component to be
tested.
2.2.2 Work Lights – Illuminate work area.
2.2.3 Red/Green Polarity Indicator Identifies positive,
negative or open circuits. The red indicator lights
when the probe tip is contacting a positive circuit.
The green indicator lights when the probe tip is
contacting a negative circuit.
2.2.4 LCD Display
2.2.5 Circuit Breaker Reset Resets the tool when the
circuit breaker is tripped
2.2.6 Power Switch – When operated conducts a positive
or negative battery current to the tip for activating
and testing the function of electrical components.
2.2.7 Mode Button – Selects the work mode: DC voltage,
scope, resistance & audible indicator.
2.2.8 Speaker – When the audible indicator is turned on,
emits a tone.
2.2.9 Auxiliary Ground Lead
2.2.10 Adaptor – Connects to the battery supply via clips or
cigarette lighter adaptor.
2.1 Introduction
Probably the most advanced automotive probe on the
market, with a huge range of functions for effective
automotive diagnostics, making short circuits and bad
earths easy to nd. Features a scope function to
visually test component signals, with the added benet of
maximum/minimum volts, frequency and duty cycle
displayed. Allows components to be activated in situ or
prior to installation. The y lead allows continuity and
polarity testing with a high-contrast colour LCD display
giving a 7mm high read-out. Features audible and posi-
tive/negative voltage indicator and two integral work lights.
6mtr lead connects to the battery supply and reaches all
areas of the vehicle. Includes a vehicle accessory socket
adaptor. Supplied in carry-case.
Original Language Version
PP100 Issue: 2 - 06/03/12
g.1
IF YOU ARE IN ANY DOUBT ABOUT ELECTRICAL
SAFETY CONSULT A QUALIFIED ELECTRICIAN.
Only for use with 2V - 24V DC systems.
DO NOT apply voltage or current to the probe that
exceeds the specified maximum of 30V DC.
DO NOT use with industrial 110V systems.
DO NOT use on any circuit directly or indirectly
connected to AC lines or any other AC power
source.
DO NOT use with any component or circuits on the
vehicle’s ignition system.
Before using this device, check the vehicle’s
electrical wiring and disconnect any part or system
sensitive to voltage and current pulses such as air
bags, electronic control modules, etc.
Always check the instructions and procedures
indicated in the vehicle service manual before
attempting to disconnect any part or sub-system of
the electrical circuit.
When not in use, store carefully in a safe, dry,
childproof location. Avoid extremes of temperature.
DO NOT use the tool around explosive gases,
vapour or dust. When the power switch is operated
(forwards or backwards), battery current is
conducted to the tip of the probe which may cause
sparks when contacting ground or certain other
circuits.
DO NOT use leads if damaged or if the wire is
bared in any way.
 DO NOT use the equipment when you are tired or
under the influence of alcohol, drugs or intoxicating
medicines.
DO NOT use this tool for any purpose other than
that for which it has been designed.
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - PROBE/SCOPE 0-30V

1. SAFETY INSTRUCTIONSINSTRUCTIONS FOR: POWER SCAN AUTOMOTIVE PROBE/SCOPE 0-30VMODEL No: PP100Thank you for purchasing a Sealey product. Manufactured

Page 2 - 3. OPERATION

3. OPERATION Original Language VersionPP100 Issue: 2 - 06/03/123.1 Basic Connections (fig.2)3.1.1 Unroll the probe cable. Connect the red battery

Page 3 - 4. TESTING PROCEDURES

Original Language VersionPP100 Issue: 2 - 06/03/124.2 Continuity Testing4.2.1 While the probe is in resistance mode, continuity can be tested o

Page 4 - Original Language Version

Original Language VersionPP100 Issue: 2 - 06/03/124.3 Signal Circuit Testing4.3.1 The tool can be used as a trouble shooting aid to test sensor

Page 5

Original Language VersionPP100 Issue: 2 - 06/03/124.6 Activating Components With a Positive (+) Voltage Within Vehicle Electrical System 4.6.1 S

Page 6 - 5. MAINTENANCE

Environmental Protection. Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted