Vue de la page 0
..................... Continuity
BAT ................. Low Battery
..................... Diode
DATA HOLD ........... Data Hold
Auto ................. Auto Ranging
AC .................. Alternating Current
DC .................. Direct Current or Voltage
1.1. PERSONAL PRECAUTIONS
When using this meter, please observe all normal safety rules concerning:
Protection against the dangers of electric current.
Protection of the meter against misuse.
Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must be replaced with genuine Sealey
leads with the same electronic ratings. Failure to do so will invalidate the warranty.
 DO NOT use leads if damaged or if the wire is bared in any way.
1.2. GENERAL SAFETY INSTRUCTIONS
Familiarise yourself with the applications, limitations and hazards of the meter.
I
F IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN
.
When the meter is linked to a measurement circuit, do not touch unused meter terminals.
When the scale of the value to be measured is unknown set the selector to the highest range available.
Before rotating the rotary switch to change functions, disconnect test leads from the circuit under test.
WARNING! Never perform resistance measurements on live circuits.
Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep your fingers behind the probe guards while measuring.
 When not in use, store the meter carefully in a safe, dry, childproof location. Storage temperature range -10°C to 50°C.
 Never apply voltage or current to the meter that exceeds the specified maximum.
The user shall ensure that test probes are correctly selected in order to prevent danger. Probes shall be selected to ensure that adequate barriers guard against
inadvertent hand contact with live conductors under test and that probes have minimal exposed probe tips. Where there is a risk of the probe tip short circuiting
with other live conductors under test, it is recommended that the exposed tip length shall not exceed 4mm.
Layout: (Refer to fig. 1.)
1. Large LCD display with symbolic signs.
2. Rotary switch.
3. Positive (+) input jack for AC/DC Voltage, AC/DC µ A/mA current, Hz/%Duty Cycle.
Ohms, Diode, Continuity, Capacitance, Temperature, (°C or °F) measurements,
RPM and Dwell.
4. COM, negative input jack.
5. 10A (positive) input jack for 10A AC or DC measurements.
6. Frequency/Duty Cycle button.
7. Range push button.
8. Relative push button.
9. Data hold.
10. Backlight button.
11. Mode push button.
INSTRUCTIONS FOR:
DIGITAL AUTOMOTIVE
ANALYSER 13 FUNCTION
WITH IC
MODEL No:TA201
Input Limits
Function
Maximum Input
V AC or V DC
600V AC, 600V DC
mA AC/DC
400mA AC/DC
A AC/DC
10A AC/DC (30 secs
max every 15 minutes)
Frequency
Resistance
Capacitance
Duty Cycle
Diode Test
Continuity
Temperature
RPM
DWELL
Pulse Width
250V AC/DC
Compact size meter with four-digit 22mm, high contrast LCD display and backlight. Features auto-ranging, data hold and auto-power-off functions. Includes
inductive coupler for fast reading of engine RPM. Supplied with probe, crocodile clips and thermocouple leads for easy hook up.
Symbols & Description
Fig.1
Inductive Pickup Test Probes
Test Clips
TA201 Issue No: 3(L) - 17/06/14
Original Language Version
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE
PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
1. SAFETY
2. FEATURES
© Jack Sealey Limited
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - 2. FEATURES

... ContinuityBAT ... Low Battery... DiodeDATA HOLD ... Data HoldAuto ... Auto

Page 2 - 3. SPECIFICATION

Range Resolution Accuracy400.0mV 0.1mV ± 0.5% of reading ± 2 digits4.000V 1mV 40.00V 10mV ±1.5% of reading ± 2 digits400.0V 100mV1000V 1V ± 1.8%

Page 3 - 4. OPERATION

 WARNING! Ensure that you read, understand and apply the safety and operational instructions before connecting the meter. Only when you are sure t

Page 4 - 6. OPERATION

4.12. Dwell Angle Measurement Dwell angle is the number of degrees through which the distributor cam rotates while the breaker points are closed.4.1