INSTRUCTIONS FOR:
COMPRESSOR 24LTR DIRECT DRIVE 2HP
110V
MODEL No: SAC2420E110V.V2
1.2. GENERAL SAFETY
3 Familiarise yourself with the application and limitations of the
compressor.
3 Ensure the compressor is in good order and condition before
use. If in any doubt do not use the unit and contact an
electrician/service agent.
WARNING! Compressor must only be serviced by an
authorised agent. DO NOT tamper with, or attempt to
adjust, pressure switch or safety valve.
3 Before moving, or maintaining the compressor ensure it is
unplugged from the mains supply and that the air tank
pressure has been vented.
3 Maintain the compressor in good condition and replace any
damaged or worn parts. Use genuine parts only. Unauthorised
parts may be dangerous and will invalidate your warranty.
3 Read the instructions relating to any accessory to be used
with this compressor. Ensure the safe working pressure of any
air appliance used exceeds compressors output pressure. If
using a spray gun, check that the area selected for spraying is
provided with an air change/ventilation system.
3 Ensure the air supply valve is turned off before disconnecting
the air supply hose.
3
© Jack Sealey Limited
1.1. ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator
to read, understand and comply with the following: You must check
all electrical products before use to ensure that they are safe. You
must inspect power cables, plugs, sockets and any other connectors
for wear or damage. You must ensure that the risk of electric shock
is minimised by the installation of appropriate safety devices. A
Residual Current Circuit Breaker (RCCB) should be incorporated in
the main distribution board. We also recommend that a Residual
Current Device (RCD) is used. It is particularly important to use an
RCD with portable products that are plugged into a supply which is
not protected by an RCCB. If in any doubt consult a qualified
electrician. You may obtain a Residual Current Device by contacting
your Sealey dealer. You must also read and understand the
following instructions concerning electrical safety:
1.1.1. The Electricity at Work Act 1989 requires that all portable
electrical appliances, if used on business premises, are
tested by a qualified electrician, using a Portable Appliance
Tester (PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of
electrical appliances responsible for the safe condition of
those appliances and the safety of the appliance operators.
If in any doubt about electrical safety, contact a qualified
electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance
is safe before connecting it to the power supply. See 1.1.1.
and 1.1.2. and use a Portable Appliance Tester.
1.1.4. Ensure that cables are always protected against short circuit
and overload.
1.1.5. Regularly inspect power supply cables and plugs for wear or
damage and check all connections to ensure that none are
loose.
1.1.6. Important: Ensure that the voltage marked on the appliance
matches the power supply to be used and that the plug is
fitted with the correct fuse.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors.
Immediately have any faulty item repaired or replaced by a
qualified electrician. When a BS EN 60309 plug is damaged,
cut the cable just above the plug and dispose of the plug
safely.
Fit a new plug according to the following instructions:
a) Connect the GREEN/YELLOW earth wire to the
earth terminal.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE
neutral wire to the
neutral terminal ‘N’.
d) After wiring, check
that there are no bare
wires, that all wires
have been connected
correctly, that the cable
outer insulation extends
beyond the cable
restraint and that the
restraint is tight.
NOTE: If using a transformer
to supply the
compressor, it must be
rated at a minimum of
2kVA to allow the
compressor to run
efficiently.
Original Language Version
SAC2420E110V.V2 Issue No:3(I)-24/11/14
g
.1
Guide to symbols
Warning: Electricity
Warning: Hot
Surface
Warning: Automatic
start up
Wear ear protection
Read the instruction
manual before use
DO NOT open the air
cock before an air hose
is attached
DO NOT operate the
compressor with
enclosure displaced
Ensure oil level
is
correctbeforerstuse
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
1. SAFETY
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - SAC2420E110V.V2

INSTRUCTIONS FOR:COMPRESSOR 24LTR DIRECT DRIVE 2HP110VMODEL No: SAC2420E110V.V21.2. GENERAL SAFETY 3 Familiarise yourself with the application a

Page 2 - 5. OPERATION

4. TOOL SELECTION IMPORTANT: Take care when selecting tools for use with the compressor. Air tool manufacturers normally express the volume

Page 3 - 6. MAINTENANCE

6. MAINTENANCE 6.3. OPERATIONS TO BE CARRIED OUT EVERY 100 HOURS: (or more frequently, if the compressor operates in a very dusty atmosphere):

Page 4 - 7. TROUBLESHOOTING

fig.6 fig.7 7. TROUBLESHOOTING FAULT CAUSE REMEDY1A) Pressure drop in the tank. Air leaks at connections. Run compressor to max. pressure, s